• senex

Products

DG2 Hydraulic Pressure Transmitter

DG2 series hydraulic pressure transmitters are manufactured on a large scale by using MEMS Bicrystal technology and digital compensation amplifier circuits. In the temperature range of -40~125℃, after digital temperature compensation, its temperature drift characteristics can meet the needs of most industrial applications.


Product Detail

Product Tags

Describe

DG2 series hydraulic pressure transmitters are manufactured on a large scale by using MEMS Bicrystal technology and digital compensation amplifier circuits. In the temperature range of -40~125℃, after digital temperature compensation, its temperature drift characteristics can meet the needs of most industrial applications. There is no welding seam and sealing ring according to the overall design of process connection and integration.These designs ensure the reliability and long-term stability of the product, so that this type of transmitter has good adaptability to pulsating voltage and overload pressure.

Application

1. Hydraulic and pneumatic control systems

2. Liquid level measurement and control

3. Petrochemical industry, environmental protection industry, air compression

4. Power station operation inspection, locomotive braking system

5. Thermal power unit

6. Light industry, machinery, metallurgy

7. Building automation, constant pressure water supply

8. Industrial process detection and control

Advantages

1. The core technology adopts MEMS Bicrystal silicate packaging technology

2. Small size, high stability, high sensitivity

3. Anti-lightning, anti-RF interference

4. Can withstand 5 times the range of breaking pressure

5. Integrated metal structure

Technical parameter indicators

Measuring Medium Various liquids, gases or steam compatible with 17-4PH/316L stainless steel
Measuring Range(Psi) 0~100,0~500,0~1000,0~1500,0~,3000,0~5000,0~10000
0~15000,0~20000(Range can be customized)
Overload Pressure 3 times full scale
Output Signal 4〜20mADC(two-wire), 0〜5VDC, 1 〜5VDC, 0. 5~4.5VDC (three-wire) RS485 I2C
Supply Voltage 10〜30VDC
Medium Temperature -40〜+125°C
Ambient Temperature -40〜+125°C
Storage Temperature -40〜+125°C
Relative Humidity ≤95% (40°C)
Accuracy (Non-Linearity, Hysteresis & Repeatability) 1%, 0.5%, 0.25%, 0.1%, 0.05%
Temperature Effect ≤±0. 05%FS / °C (Temperature span-20〜+85°C,temperature effects including zero and span)
Temperature Compensation Span -40〜85 °C
Stability ±0. 15%FS/Year (Typical value)
Media Touching Material 17-4PH/316L Stainless steel
Cover Material 304 or 316 Stainless steel
Installation method Threaded installation
Electrical Connections Four-core shielded cable (protection grade IP68), HSM connector, M12* 1 connector (optional)

  • Previous:
  • Next:

  • Write your message here and send it to us