• senex

Products

DP1300-M Series Gauge or Absolute Pressure Transmitters – Maxonic


Product Detail

Product Tags

Related Video

Feedback (2)

Our mission is usually to turn into an innovative provider of high-tech digital and communication devices by furnishing benefit added design and style, world-class manufacturing, and service capabilities for Customized Pressure Transducer, Liquid Level Pressure Sensor, 0-1000 Psi Pressure Sensor, Customers' reward and fulfillment are usually our biggest objective. Please make contact with us. Give us a probability, provide you with a surprise.
DP1300-M Series Gauge or Absolute Pressure Transmitters – Maxonic Detail:

DP1300-M gauge pressure/absolute pressure transmitter has a wide range of applications, including petroleum, chemical, gas, electricity, military, water conservancy, food and etc.

1. Independent innovation and anti-overload structure make the transmitter more secure.
2. Unique dual sensor technology, accurate and stable measurement.
3. This kind of monosilicon type smart transmitter has excellent insulation performance between the core components and the shell, which ensures that the sensor output signal will not be disturbed on site.

Standard Specification Span adjustment based on standard zero point, with stainless steel 316 L diaphragm, filling liquid is silicone oil.
Performance Specification Reference Accuracy of Adjustment Span (Includes linearity from zero, hysteresis and repeatability): ± 0.075%
TD> 10 ( TD=Maximum span/adjustment span): ±(0.0075×TD)%
Square root output accuracy is 1.5 times the linear reference accuracy above
Ambient Temperature Effect Span Code - 20℃~65℃ Total impact
B/L ±( 0.30×TD+ 0.20 )% ×Span
Other ±( 0.20×TD+ 0.10 )% ×Span
Span Code - 40℃~- 20℃ and 65℃~85℃ Total impact
B/L ±( 0.30×TD+ 0.20 )% ×Span
Other ±( 0.20×TD+ 0.10 )% ×Span
Over-span Effect ±0 . 075% ×Span
Span Code Amount of Influence
Long Term Stability B/L ±0.2% ×Span/ 1Year
Other ±0.1% ×Span/ 1Year
Power Impact ±0.001% / 10 V(12~42 V DC)
Measuring Range(Gauge pressure transmitter) kpa/ mbar kpa/ mbar
B 0.6~6 /- 6~6 6 ~ 60 /- 60 ~ 60
C 2 ~ 40 /- 40 ~ 40 0.02 ~ 0.4 /- 0.4 ~ 0.4
D 2.5 ~ 250 /- 100 ~ 250 0.025 ~ 2.5 /- 1 ~ 2.5
F 30 ~ 3000 /- 100 ~ 3000 0.3 ~ 30 /- 1 ~ 30
G 100 ~ 10000 /- 1000 ~ 100000 1 ~ 100 /- 1 ~ 100
H 210 ~ 21000/-1000 ~ 210000 2.1 ~ 210 /- 1 ~ 210
I 400 ~ 40000 /-1000 ~ 400000 4 ~ 400 /- 1 ~ 400
J 600 ~ 60000 /-1000 ~ 600000 6 ~ 600 /- 1 ~ 60
Measuring Range(Absolute pressure transmitter) kpa/ mbar kpa/ mbar
L 2 ~ 40 /- 40 ~ 40 0.02 ~ 0.4 /- 0.4 ~ 0.4
M 2 . 5 ~ 250 /- 100 ~ 250 0.025 ~ 2.5 /- 1 ~ 2.5
O 30 ~ 3000 /- 100 ~ 3000 0.3 ~ 30 /- 1 ~ 30
Span Limit Within the upper and lower limits of the span, it can be adjusted arbitrarily;
It is recommended to select a span code with the lowest possible turndown ratio to optimize performance characteristics.
Zero Point Setting Zero point and span can be adjusted to any value within the measurement span in the table (as long as: calibration span ≥ minimum span).
Installation Location Influence The change of the installation position parallel to the diaphragm surface will not cause zero drift effect. If the change of the installation position and the diaphragm surface exceeds 90°, the zero position effect in the span of < 0.06 Psi will occur, which can be corrected by adjusting the zero adjustment, with no range effect.
Output Two-wire, 4~20 m ADC, HART output digital communication can be selected, linear or square root output can also be selected.
Output signal limit:Imin= 3.9 m A, Imax= 20.5 m A
Alarm Current Low report mode(Mini): 3.7 m A
High report mode (Max): 21 m A
Non-reporting mode (hold): keep the effective current value before the fault and report
Standard setting of alarm current: high mode
Response Time The damping constant of the amplifier part is 0.1 s and the sensor time constant is 0.1 to 1.6 s, depending on the range and range ratio.The additional adjustable time constant is 0.1 to 60 s.
Preheat Time < 15 s
Ambient Temperature - 40~85℃
With LCD display and fluororubber sealing ring: – 20~65℃
Storage Temperature - 50~85℃
With LCD display: – 40~85℃
Pressure Limit From vacuum to maximum range
Material Diaphragm: Stainless Steel 316 L, C-276 alloy
Process Connection: Stainless Steel 316L
Transmitter Cover: Aluminum alloy material, epoxy resin sprayed on the surface
Filling Fluid: Silicone Oil
Protection Class IP67

Product detail pictures:

DP1300-M Series Gauge or Absolute Pressure Transmitters – Maxonic detail pictures

DP1300-M Series Gauge or Absolute Pressure Transmitters – Maxonic detail pictures

DP1300-M Series Gauge or Absolute Pressure Transmitters – Maxonic detail pictures


Related Product Guide:

Our eternal pursuits are the attitude of "regard the market, regard the custom, regard the science" plus the theory of "quality the basic, have faith in the main and management the advanced" for DP1300-M Series Gauge or Absolute Pressure Transmitters – Maxonic , The product will supply to all over the world, such as: Singapore, Algeria, Austria, Be sure to feel cost-free to send us your specs and we are going to respond for you asap. We have got a experienced engineering team to serve for the every single comprehensive needs. Free samples may be sent for yourself personally to know far more facts. So that you can meet your desires, please actually feel cost-free to contact us. You could send us emails and call us straight. Additionally, we welcome visits to our factory from all over the world for much better recognizing of our corporation. nd merchandise. In our trade with merchants of several countries, we often adhere to the principle of equality and mutual advantage. It is our hope to market, by joint efforts, both trade and friendship to our mutual benefit. We look forward to getting your inquiries.
  • This is a very professional wholesaler, we always come to their company for procurement, good quality and cheap.
    5 Stars By Pearl Permewan from Georgia - 2017.08.28 16:02
    A good manufacturers, we have cooperated twice, good quality and good service attitude.
    5 Stars By Carol from Sheffield - 2018.12.14 15:26
    Write your message here and send it to us