DP1300-M Series Gauge or Absolute Pressure Transmitters

DP1300-M gauge pressure/absolute pressure transmitter is used to measure liquid level, density and pressure of liquid, gas or steam, and then convert it into 4~20mADC HART current signal output. DP1300-M can also be used with RST375 handheld terminal or RSM100 Modems communicate with each other, through them for parameter setting, process monitoring, etc. The absolute pressure sensor is only installed on the high pressure side of the sensor diaphragm box as a reference value for static pressure measurement and compensation.


Product Detail

Product Tags

Application

DP1300-M gauge pressure/absolute pressure transmitter has a wide range of applications, including petroleum, chemical, gas, electricity, military, water conservancy, food and etc.

Advantages

1. Independent innovation and anti-overload structure make the transmitter more secure.
2. Unique dual sensor technology, accurate and stable measurement.
3. This kind of monosilicon type smart transmitter has excellent insulation performance between the core components and the shell, which ensures that the sensor output signal will not be disturbed on site.

Technical parameter indicators

Standard Specification Span adjustment based on standard zero point, with stainless steel 316 L diaphragm, filling liquid is silicone oil.
Performance Specification
 
Reference Accuracy of Adjustment Span (Includes linearity from zero, hysteresis and repeatability): ± 0.075%
TD> 10 ( TD=Maximum span/adjustment span): ±(0.0075×TD)%
Square root output accuracy is 1.5 times the linear reference accuracy above
 
Ambient Temperature Effect
Span Code - 20℃~65℃ Total impact
B/L ±( 0.30×TD+ 0.20 )% ×Span
Other ±( 0.20×TD+ 0.10 )% ×Span
Span Code - 40℃~- 20℃ and 65℃~85℃ Total impact
B/L ±( 0.30×TD+ 0.20 )% ×Span
Other ±( 0.20×TD+ 0.10 )% ×Span
Over-span Effect ±0 . 075% ×Span
  Span Code Amount of Influence
Long Term Stability B/L ±0.2% ×Span/ 1Year
Other ±0.1% ×Span/ 1Year
  Power Impact ±0.001% / 10 V(12~42 V DC)
  Measuring Range(Gauge pressure transmitter) kpa/ mbar kpa/ mbar
B 0.6~6 /- 6~6 6 ~ 60 /- 60 ~ 60
C 2 ~ 40 /- 40 ~ 40 0.02 ~ 0.4 /- 0.4 ~ 0.4
D 2.5 ~ 250 /- 100 ~ 250 0.025 ~ 2.5 /- 1 ~ 2.5
F 30 ~ 3000 /- 100 ~ 3000 0.3 ~ 30 /- 1 ~ 30
G 100 ~ 10000 /- 1000 ~ 100000  1 ~ 100 /- 1 ~ 100
H 210 ~ 21000/-1000 ~ 210000 2.1 ~ 210 /- 1 ~ 210
I 400 ~ 40000 /-1000 ~ 400000  4 ~ 400 /- 1 ~ 400
J 600 ~ 60000 /-1000 ~ 600000 6 ~ 600 /- 1 ~ 60
Measuring Range(Absolute pressure transmitter) kpa/ mbar kpa/ mbar
L 2 ~ 40 /- 40 ~ 40 0.02 ~ 0.4 /- 0.4 ~ 0.4
M 2 . 5 ~ 250 /- 100 ~ 250 0.025 ~ 2.5 /- 1 ~ 2.5
O 30 ~ 3000 /- 100 ~ 3000 0.3 ~ 30 /- 1 ~ 30
Span Limit Within the upper and lower limits of the span, it can be adjusted arbitrarily;
It is recommended to select a span code with the lowest possible turndown ratio to optimize performance characteristics.
Zero Point Setting Zero point and span can be adjusted to any value within the measurement span in the table (as long as: calibration span ≥ minimum span).
Installation Location Influence The change of the installation position parallel to the diaphragm surface will not cause zero drift effect. If the change of the installation position and the diaphragm surface exceeds 90°, the zero position effect in the span of < 0.06 Psi will occur, which can be corrected by adjusting the zero adjustment, with no range effect.
  Output Two-wire, 4~20 m ADC, HART output digital communication can be selected, linear or square root output can also be selected.
Output signal limit:Imin= 3.9 m A, Imax= 20.5 m A
Alarm Current Low report mode(Mini): 3.7 m A
High report mode (Max): 21 m A
Non-reporting mode (hold): keep the effective current value before the fault and report
Standard setting of alarm current: high mode
Response Time The damping constant of the amplifier part is 0.1 s and the sensor time constant is 0.1 to 1.6 s, depending on the range and range ratio.The additional adjustable time constant is 0.1 to 60 s.
Preheat Time < 15 s
Ambient Temperature - 40~85℃
With LCD display and fluororubber sealing ring: - 20~65℃
Storage Temperature - 50~85℃
With LCD display: - 40~85℃
Pressure Limit From vacuum to maximum range
Material Diaphragm: Stainless Steel 316 L, C-276 alloy
Process Connection: Stainless Steel 316L
Transmitter Cover: Aluminum alloy material, epoxy resin sprayed on the surface
Filling Fluid: Silicone Oil
Protection Class IP67