Sheathed thermocouple is widely used in aviation, atomic energy, petrochemical, metallurgy, machinery, electric power and other industrial sectors in technological fields.
1. Large temperature measurement range.
2. Short thermal response time, fast response speed and small outer diameter.
3. Rapid response to temperature changes, reducing dynamic errors.
4. Easy installation, long service life, good air tightness and good mechanical strength.
5. Can be used under vibration, low temperature and high temperature conditions.
6. Bendable installation and use.
1. Accuracy
Graduation |
Tolerance Grade |
|||
Ⅰ |
Ⅱ | |||
Tolerance Value |
Measuring Range ℃ |
Tolerance |
Measuring Range ℃
|
|
K |
±1.5℃ |
-40~+375 |
±2.5℃ |
-40~+333 |
±0.004|t| |
375~1000 |
±0.0075|t| |
333~1200 |
Note: “t” is the actual temperature which can be expressed in degrees of temperature, or expressed as a percentage of the actual temperature and we should take the larger value.
2. Protection Grade: IP68.
3. Explosion-proof Grade: ExdIICT6.
4. Diameter: 0.5-12.7 (can be customized) and can be equipped with thermowell.
5. Optional temperature conversion module.