DP1300-DP Series differential pressure transmitter is used to measure the liquid level, density, pressure, and flow of liquid, gas or steam, and then convert it into a 4-20mADC HART current signal output.DP1300-DP Series differential pressure transmitter can also communicate with HART375 hand-held Parameter setting, process monitoring, etc. This sensor module adopts all welding technology and has an integrated overload diaphragm, an absolute pressure sensor, a temperature sensor and a differential pressure sensor inside. The protection level of this product can reach IP67.


Product Detail

Product Tags

We’ve been convinced that with joint efforts, the enterprise between us will bring us mutual benefits. We are able to assure you product or service quality and aggressive cost for Hot sale Comprehensive Protection Digital Tire Pressure Gauge for Pneumatic Instrument, To achieve reciprocal advantages, our business is widely boosting our tactics of globalization in terms of communication with overseas clients, rapidly delivery, the top excellent and long-term cooperation.
We’ve been convinced that with joint efforts, the enterprise between us will bring us mutual benefits. We are able to assure you product or service quality and aggressive cost for china liquid level sensor, Diaphragm Pressure Transducer, flush diaphragm pressure transmitter, Hydraulic Pressure Transmitter, We are introduced as a one of the growing manufacture supplier and export of our products. We have a team of dedicated trained professional who take care the quality and timely supply. If you are looking for Good Quality at a good price and timely delivery. Do contact us.
DP1300-DP Series differential pressure transmitter has high measurement accuracy, strong overload capacity, good stability, easy installation, and is suitable for various types of pressure measurement applications. It is widely used in power, metallurgy, petrochemical and pharmaceutical industries.

1. The monosilicon type belongs to the latest generation of differential pressure sensor technology, and has excellent performance in measurement accuracy, turndown ratio, overvoltage capability, and stability.

2. Compared with differential pressure sensors of the same accuracy level, the yield rate of monosilicon type is much higher than that of other early technologies such as capacitive type. There is no need for precision screening in the production process, and mass production of high-precision products can be realized.

Standard Specification Span adjustment based on standard zero point, with stainless steel 316 L diaphragm, filling liquid is silicone oil.
Performance Specification Reference Accuracy of Adjustment Span (Includes linearity from zero, hysteresis and repeatability): ± 0 . 075%
TD> 10 ( TD=Maximum span/adjustment span): ±(0.0075×TD)%
Square root output accuracy is 1.5 times the linear reference accuracy above
Ambient Temperature Effect Span Code - 20℃~65℃  Total impact
A ±( 0 . 45×TD+ 0 . 25 )% ×Span
B ±( 0 . 30×TD+ 0 . 20 )% ×Span
C/ D/ F ±( 0 . 20×TD+ 0 . 10 )% ×Span
Span Code - 40℃~- 20℃ and 65℃~85℃  Total impact
A ±( 0 . 45×TD+ 0 . 25 )% ×Span
B ±( 0 . 30×TD+ 0 . 20 )% ×Span
C/ D/ F ±( 0 . 20×TD+ 0 . 10 )% ×Span
Over-span Effect ±0 . 075% ×Span
Span Code Amount of Influence
Static Pressure Effect A ±( 0 . 5% Span)/ 580Psi
B ±( 0 . 3% Span)/ 1450 Psi
C/ D/ F ±( 0 . 1% Span)/ 1450 Psi
Performance Specification Overvoltage Effects Span Code Amount of Influence
A ±0 . 5% ×Span/580Psi
B ±0 . 2% ×Span/ 2320Psi
C/ D/ F ±0 . 1% ×Span/ 2320Psi
Long Term Stability Span Code Amount of influence
A ±0 . 5% ×Span/ 1Year
B ±0 . 2% ×Span/ 1Year
C/ D/ F ±0 . 1% ×Span/ 1Year
Power Impact C/D/F ±0 . 001% / 10 V( 12~42 V DC)
Measuring Range kpa/ mbar kpa/ mbar
A 0 . 1~1 / 1~10 - 1~1 /- 10~10
B 0 . 2~6 / 2~60 - 6~6 /- 60~60
C 0 . 4~40 / 4~400 - 40~40 /- 400~400
D 2 . 5~250 / 25~2500 - 250~250 /- 2500~2500
F 30~3000 / 0 . 3~30 bar - 500~3000 /- 5~30 bar
Span Limit Within the upper and lower limits of the span, it can be adjusted arbitrarily;
It is recommended to select a range code with the lowest possible turndown ratio to optimize performance characteristics.
Zero Point Setting Zero point and span can be adjusted to any value within the measurement range in the table (as long as: calibration span ≥ minimum span).
Installation Location Influence The change of the installation position parallel to the diaphragm surface will not cause zero drift effect. If the change of the installation position and the diaphragm surface exceeds 90°, the zero position effect in the span of < 0.06 Psi will occur, which can be corrected by adjusting the zero adjustment, with no range effect.
Output Two-wire, 4~20 m ADC, HART output digital communication can be selected, linear or square root output can also be selected.
Output signal limit: Imin= 3.9 m A, Imax= 20.5 m A
Alarm Current Low report mode (Mini): 3.7 m A
High report mode (Max): 21 m A
Non-reporting mode (hold): keep the effective current value before the fault and report
Standard setting of alarm current: high mode
Response Time The damping constant of the amplifier part is 0.1 s; the sensor time constant is 0.1 to 1.6 s, depending on the range and range ratio. Additional adjustable time constants are: 0.1 to 60 s. The effect on non-linear output, such as the square root function, depends on the function and can be calculated accordingly.
Preheat Time < 15 s
Ambient Temperature - 40~85℃
With LCD display and fluororubber sealing ring: – 20~65℃
Storage Temperature - 50~85℃
With LCD display:- 40~85℃
Work Pressure Rated working pressure is divided into: 2320 Psi, 3630Psi, 5800 Psi
Static Pressure Limit From the absolute pressure of 0.5Psi to the rated pressure, the protective pressure can be greater than 1.5 times of the rated pressure, and it is applied to both sides of the transmitter at the same time.
One-way Overload Limit One-way overload up to rated pressure
Material Measuring Capsule: Stainless Steel 316 L
Diaphragm: Stainless Steel 316 L, C-276 alloy
Process Flange: Stainless Steel 304
Nuts and Bolts: Stainless Steel (A 4 )
Filling Fluid: Silicone Oil
Protection Class IP67

We’ve been convinced that with joint efforts, the enterprise between us will bring us mutual benefits. We are able to assure you product or service quality and aggressive cost for Hot sale Comprehensive Protection Digital Tire Pressure Gauge for Pneumatic Instrument, To achieve reciprocal advantages, our business is widely boosting our tactics of globalization in terms of communication with overseas clients, rapidly delivery, the top excellent and long-term cooperation.
Hot sale china liquid level sensor,hydraulic pressure transmitter,flush diaphragm pressure transmitter,diaphragm pressure transducer, We are introduced as a one of the growing manufacture supplier and export of our products. We have a team of dedicated trained professional who take care the quality and timely supply. If you are looking for Good Quality at a good price and timely delivery. Do contact us.