With our leading technology at the same time as our spirit of innovation,mutual cooperation, benefits and development, we are going to build a prosperous future alongside one another with your esteemed enterprise for Dynamic Pressure Transducer, Sensor Level Water, Refrigerant Liquid Level Sensor, We sincerely welcome clients from both of those at your home and overseas to occur to barter business enterprise with us.
OEM/ODM Supplier Monocrystalline Silicon Pressure Sensor - DP1300-M Series Gauge or Absolute Pressure Transmitters – Maxonic Detail:

DP1300-M gauge pressure/absolute pressure transmitter has a wide range of applications, including petroleum, chemical, gas, electricity, military, water conservancy, food and etc.

1. Independent innovation and anti-overload structure make the transmitter more secure.
2. Unique dual sensor technology, accurate and stable measurement.
3. This kind of monosilicon type smart transmitter has excellent insulation performance between the core components and the shell, which ensures that the sensor output signal will not be disturbed on site.

Standard Specification Span adjustment based on standard zero point, with stainless steel 316 L diaphragm, filling liquid is silicone oil.
Performance Specification Reference Accuracy of Adjustment Span (Includes linearity from zero, hysteresis and repeatability): ± 0.075%
TD> 10 ( TD=Maximum span/adjustment span): ±(0.0075×TD)%
Square root output accuracy is 1.5 times the linear reference accuracy above
Ambient Temperature Effect Span Code - 20℃~65℃ Total impact
B/L ±( 0.30×TD+ 0.20 )% ×Span
Other ±( 0.20×TD+ 0.10 )% ×Span
Span Code - 40℃~- 20℃ and 65℃~85℃ Total impact
B/L ±( 0.30×TD+ 0.20 )% ×Span
Other ±( 0.20×TD+ 0.10 )% ×Span
Over-span Effect ±0 . 075% ×Span
Span Code Amount of Influence
Long Term Stability B/L ±0.2% ×Span/ 1Year
Other ±0.1% ×Span/ 1Year
Power Impact ±0.001% / 10 V(12~42 V DC)
Measuring Range(Gauge pressure transmitter) kpa/ mbar kpa/ mbar
B 0.6~6 /- 6~6 6 ~ 60 /- 60 ~ 60
C 2 ~ 40 /- 40 ~ 40 0.02 ~ 0.4 /- 0.4 ~ 0.4
D 2.5 ~ 250 /- 100 ~ 250 0.025 ~ 2.5 /- 1 ~ 2.5
F 30 ~ 3000 /- 100 ~ 3000 0.3 ~ 30 /- 1 ~ 30
G 100 ~ 10000 /- 1000 ~ 100000 1 ~ 100 /- 1 ~ 100
H 210 ~ 21000/-1000 ~ 210000 2.1 ~ 210 /- 1 ~ 210
I 400 ~ 40000 /-1000 ~ 400000 4 ~ 400 /- 1 ~ 400
J 600 ~ 60000 /-1000 ~ 600000 6 ~ 600 /- 1 ~ 60
Measuring Range(Absolute pressure transmitter) kpa/ mbar kpa/ mbar
L 2 ~ 40 /- 40 ~ 40 0.02 ~ 0.4 /- 0.4 ~ 0.4
M 2 . 5 ~ 250 /- 100 ~ 250 0.025 ~ 2.5 /- 1 ~ 2.5
O 30 ~ 3000 /- 100 ~ 3000 0.3 ~ 30 /- 1 ~ 30
Span Limit Within the upper and lower limits of the span, it can be adjusted arbitrarily;
It is recommended to select a span code with the lowest possible turndown ratio to optimize performance characteristics.
Zero Point Setting Zero point and span can be adjusted to any value within the measurement span in the table (as long as: calibration span ≥ minimum span).
Installation Location Influence The change of the installation position parallel to the diaphragm surface will not cause zero drift effect. If the change of the installation position and the diaphragm surface exceeds 90°, the zero position effect in the span of < 0.06 Psi will occur, which can be corrected by adjusting the zero adjustment, with no range effect.
Output Two-wire, 4~20 m ADC, HART output digital communication can be selected, linear or square root output can also be selected.
Output signal limit:Imin= 3.9 m A, Imax= 20.5 m A
Alarm Current Low report mode(Mini): 3.7 m A
High report mode (Max): 21 m A
Non-reporting mode (hold): keep the effective current value before the fault and report
Standard setting of alarm current: high mode
Response Time The damping constant of the amplifier part is 0.1 s and the sensor time constant is 0.1 to 1.6 s, depending on the range and range ratio.The additional adjustable time constant is 0.1 to 60 s.
Preheat Time < 15 s
Ambient Temperature - 40~85℃
With LCD display and fluororubber sealing ring: – 20~65℃
Storage Temperature - 50~85℃
With LCD display: – 40~85℃
Pressure Limit From vacuum to maximum range
Material Diaphragm: Stainless Steel 316 L, C-276 alloy
Process Connection: Stainless Steel 316L
Transmitter Cover: Aluminum alloy material, epoxy resin sprayed on the surface
Filling Fluid: Silicone Oil
Protection Class IP67

Product detail pictures:

OEM/ODM Supplier Monocrystalline Silicon Pressure Sensor - DP1300-M Series Gauge or Absolute Pressure Transmitters – Maxonic detail pictures

OEM/ODM Supplier Monocrystalline Silicon Pressure Sensor - DP1300-M Series Gauge or Absolute Pressure Transmitters – Maxonic detail pictures

OEM/ODM Supplier Monocrystalline Silicon Pressure Sensor - DP1300-M Series Gauge or Absolute Pressure Transmitters – Maxonic detail pictures


Related Product Guide:

Our pursuit and enterprise goal is to "Always satisfy our customer requirements". We keep on to establish and style and design outstanding top quality goods for both our outdated and new prospects and realize a win-win prospect for our clientele likewise as us for OEM/ODM Supplier Monocrystalline Silicon Pressure Sensor - DP1300-M Series Gauge or Absolute Pressure Transmitters – Maxonic , The product will supply to all over the world, such as: British, Juventus, Houston, Our company is working by the operation principle of "integrity-based, cooperation created, people oriented, win-win cooperation". We hope we can have a friendly relationship with businessman from all over the world.
  • The factory workers have rich industry knowledge and operational experience, we learned a lot in working with them,we are extremely grateful that we can encount a good company has excellent wokers.
    5 Stars By Athena from India - 2018.09.21 11:01
    A nice supplier in this industry, after a detail and careful discussion, we reached a consensus agreement. Hope that we cooperate smoothly.
    5 Stars By Jean from Slovakia - 2017.08.21 14:13
    Write your message here and send it to us